Lab / measuring devices


 

The hand-held installation tester METREL-MI 3123  is intended in general for the following tests and measurements

     - Standard earthing resistance measurement with spikes

      - Selective earthing resistance test with one current clamp
      - contactless earthing resistance with two current clamps
      - Specific earth resistance measurement

 

 

 

The C.A 6505 makes industrial equipment inspection and maintenance testing particularly simple.

The leading microprocessor system of Megahometer maintenances testing methods such are:

Large measurement range . . . . . from 10KΩ To 10TΩ

Fixed test voltages and programmable test voltages. . . .5100 V

Capacity measurement. . . . . . . . . . . . . . .50  μF

Leakage current measurement. . . . . . . . . . . . .3 ma

 

 

 

C.A 6547 megohmmeter can be used for quantitative and qualitative analysis of insulation. It also automatically measures voltage, capacitance and residual current. Has wide range from 30kΩ to 10TΩ !

4 fixed test voltages: 500 / 1,000 / 2500 and 5,000V

 

 

 

Rugged and leakproof, the C.A 6240 is a top-of-the-range product designed for on-site, workshop or laboratory use.

Wade range: . . . . . . . . . . . . . . . 5μΩ to 400Ω

 

 

 

 

 

 

Test set UIM-90m is intended for defining breakdown voltage of circuit-breaker oil and other sampling liquid dielectrics.

Maximum breakdown voltage. . . . . . . . . . . . . .80kv

 

 

 

 

 

K540 complete set is designed for power, voltage and power for the variable measuring the three-phase power one   networks and unequal phase loading time.
Three-phase and provides a consistent set of measuring otkhpazian networks (with order) for each phase voltage, current and power measurements. Total capacity of three-phase network is determined by measuring each phase.

 

 

IАП-06  is  intended to determine the exact breakdown of Cable lines with acoustic method for jointly working with the generator of electric shock impulses.

 

 

 

 

 

"искра_3М" high voltage  cable is designed for determining the distance to the place of injury. Device allows you to:

- discover and determine the distance to the place of injury and the uniformity of symmetrical and non symmetrical cable.

 

 

 

 

Reference standard of the unit of scale transformation of voltage and strength of alternative current For attestation, verification and calibration of scale transformers of voltage and current;
 accuracy of measurements:
voltage of alternating current – 0.02
 alternating current force – 0,05